CUR2144 Ventilator

Product Rating:
5/5

Description

**Acute Care Ventilation:-

*Acute Care Ventilation:- Remarkable performance and features in a portable and intuitive package. The Flight 60 ventilator is designed to address a wide range of hospital needs while improving patients’ comfort & independence.

*Full Ventilation Package:-

  • Advanced ventilation modes
  • Pressure and Volume
  • New Volume Guarantee mode
  • New Bi-Level
  • Invasive & non-invasive
  • Pediatric to adult – 30 ml – 2.2 liter
  • Advanced Monitoring
  • Waveforms and Loops
  • Trends – display up to 72 hours
  • Lung Mechanics:
  • Static/dynamic Compliance
  • Resistance
  • Plateau Pressure
  • Auto PEEP”

*Safe, Intuitive and Mobile:- 

  • Extensive alarm system
  • Exhaled volume monitoring – meeting critical care requirements
  • Oxygen sensor – built in
  • 7” touch screen clearly visible from a distance
  • Lightweight & portable
  • High pressure and low flow O2 ports
  • Fully independent internal compressor
  • Easily connecting to hospitals’ IT systems

**Technical Specifications:-

1.*MODES:-

  • ACMV – PCV/VCV/PRVC
  • SIMV – PCV/VCV/PRVC
  • SPONT (CPAP, BPAP)
  • Volume Guarantee
  • B-Lev (Bi-Phasic, APRV)”

2.*CONTROLS:-

  • NPPV- OFF/LOW/HIGH (leak compensation up to 30 LPM)
  • VG Mode- VtG (Tidal Volume Guarantee) MVG (Minute Volume Guarantee)
  • SIGH- ON/OFF
  • Synchronized Nebulizer – ON/OFF
  • Nebulization Period – OFF, 5 to 60 min
  • 2min 100% O2 Function – ON/OFF
  • Tidal Volume – 30 to 2,200 ml
  • Breath Rate – 1 to 99 b/min
  • Inspiration Time (Ti) – 0.1 to 3.0 sec
  • Flow – 2 to 100 L/min
  • Pressure Control – 5 to 80 cmH2O
  • Pressure Support (PSV) – 0 to 60 cmH2O
  • PEEP/CPAP- 0 to 40 cmH2O
  • Pressure Trigger- -20.0 to -0.1 cmH2O
  • Flow Trigger – 1 to 20 LPM
  • Rise Profile – 5 levels
  • PSV Ti – 0.1 to 3 sec
  • PSV Flow Termination – 10% to 90%
  • Volume Control – Time/Flow
  • Flow Waveform – Square/Descending
  • FiO2 – 21% to 100%
  • FiO2 Sensor – ON, OFF, Calibrate
  • Manual Breath – 0 to 3 sec
  • Panel Lock – ON/OFF
  • Trends – ON/OFF/Clear
  • Maneuvers – Inspiratory Hold, Expiratory Hold
  • Hold Length – 1 to 6 seconds

3.*VG Mode Controls:-

  • Target VtG – 30 to 2,200 ml
  • PSV min – 0 to 60 cmH2O
  • PSV max – 5 to 60 cmH2O
  • Trigger Delay- ON/OFF

4.*B-Lev Controls:-

  • P High – 3 to 60 cmH2O
  • P Low – 0 to 30 cmH2O
  • T High (Ti)- 1 to 15 sec
  • T Low – 0.5 to 5 sec
  • Inverse I:E – 30:1

5.*ALARMS (variable):- 

  • Alarm Prioritization – 3 Levels – Caution, Medium, High
  • Low Minute Volume – 0.0 to 50 L/min
  • Low Pressure – OFF, 1 to 98 cmH2O
  • High Pressure – 4 to 99 cmH2O
  • High Minute Volume – 0.1 to 50 L/min
  • High FiO2 – 31% to 99%, OFF
  • Low FiO2 – OFF, 22% to 90%
  • High Rate – OFF, 1 to 99 bpm
  • Low Rate – OFF, 1 to 99 bpm
  • Low Vte – OFF, 10 to 2,200ml
  • Low Vti – OFF, 10 to 2,200ml
  • Apnea/Back-Up Ventilation – 10-60 sec

6.*ALARMS (automatic):-Check Circuit (Circuit Disconnect), Low/Empty Battery, O2 Supply Failed, Check O2 Sensor, Target Volume not reached.

7.*MONITORED PARAMETERS:-

  • Waveforms – Pressure, Flow, Volume
  • Loops – Pressure/Volume & Flow/Volume
  • Trends – Rate, Peak Inspiratory Pressure & Vte (up to 72 hours)
  • Airway Pressure LED Gauge – -10 to 120 cmH2O
  • Peak Inspiratory Pressure – 0 to 120 cmH2O
  • Base Pressure – 0 to 99 cmH2O
  • Mean Pressure – 0 to 99 cmH2O
  • Exhaled Tidal Volume – 0 to 10L
  • Exhaled Tidal Volume – 0 to 10L
  • Inhaled Tidal Volume – 0 to 10L
  • Inhaled Minute Volume – 0 to 99L
  • Actual Breath Rate – 0 to 99 b/min
  • Peak Inspiratory Flow – 1 to 120 L/min
  • RSBI – 0 to 200 min*L
  • Lung Mechanics – Static and Dynamic Compliance, Resistance, Plateau Pressure, Auto PEEP
  • FiO2 – 21% to 100%
  • I:E Ratio – 1:99 to 3:1
  • Battery Level – 100% to 0%, Low, Empty

8.*SPECIAL FUNCTIONS:-

  • Buzzer Level – LOW/HIGH
  • Keypad Buttons – Keypad buttons with audible indicator
  • Power Save – ON/OFF/NIGHT
  • Languages – English, French, German, Greek, Hungarian, Italian, Polish, Portu- guese, Russian, Spanish, Turkish
  • Quick Start – 5 preset ventilation modes

9.*SIZE AND WEIGHT:-

  • Dimensions (WxLxH) – 29 x 28 x 25 cm / 11.4” x 11.0”x 9.8”
  • Weight – 6.3 Kg / 13.9 lbs
  • 6.9 Kg / 15.2 lbs (with integrated mixer)

10.*OXYGEN:-

  • O2 Mixer (optional) – Internal integral, electronically controlled
  • High Pressure – 35 to 90 psi
  • Low Flow Port – 0 to 15 L/min
  • Low Flow Blending Bag – 0 to 15 L/min

11.*POWER SUPPLY:-

  • AC Power Inlet – 100 to 240 VAC, 50-60Hz
  • DC Power Inlet – 12 to 15 VDC
  • Internal Batteries – Hot Swappable 12 hours operation
  • Charging Time – Up to 3 hours

12.*COMMUNICATIONS:-

  • USB x2 – Download Logs, SW Upgrade
  • RS232 x2 -Remote Alarm and Monitoring

13.*ENVIRONMENTAL:-

  • Operation Temperature – (-18OC to 50OC / -0.4OF to 122OF)
  • Storage Temperature – (-20OC to 71OC / -4.0OF to 160OF)
  • Relative Humidity – 15% to 95% at 31OC / 88OF
  • Operation Altitude – 110 kPa to 70 kPa
  • Water/Dust Resistance – IP34 (splash proof)

14.*STANDARDS:- IEC 60601-1 ,IEC 60601-1-2 ,IEC 60601-2-12, ASTM 1246F ,ISO 10651-2/3, RTCA DO