CUR2135 Biphasic Defibrillator

Product Rating:
5/5

Description

**Biphasic Defibrillator:-Biphasic Defibrillator is an efficient, easy to use defibrillation and monitor device with Manual Defibrillation Mode, Monitor Mode & AED Mode.

Biphasic Technology
50 mm Internal Thermal Printer
65 Hours of all parameter Data Storage
Paddle for Adult and Pediatric (Quick Convert)
Charge time less than 7 secs
Monitor display indicates selected & delivered energy
Real-time monitoring of battery level

**Technical Specifications:-

*Display:-

Screen Type: High-resolution display
Screen Size: 7″ (17.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm On/Off,Sp02, AED Functions and Prompts, Alarm Selection head and Limits, Delivered Energy

           *Defibrillator:-

• Waveform: Biphasic
• Energy Display: Monitor display indicated both selected Sp02 Module (Optional) and delivered energy
• Charge Prompt Type: Voice and visual prompts
• Electrode impedance Measurement: Range: 0-250 ohms

          *ECG Monitoring:-

• Patient Connection: 3-lead ECG cable or 5-lead ECG cable, paddles
• Lead Selection: Displayed on monitor, paddles,1,2,3 AVR, AVC, AVF, V
• ECG Size: 0.25, 0.5, 1 , 1.5, 2,4 cm/mV display on monitor
• Heart Rate: 20-300BPM
• Heart Rate Alarm: Or/Off displayed on monitor, user-selectable.
• Smart Alarms: Beeper/voice prompts indicated Ventricular fibrillation shockable rhythm

          *Battery:

• Type: Rechargeable, Ni-MH battery, 12V
• Operating Time: For a new, fully charged battery 60 defibrillator discahrges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different function.

         *Recorder:-

• Paper: 50mm thermal
• Speed: 12.5 mm/sec, 25 mm/sec, 50 mm/sec. User selectable 6-second delay.
• Printing Method: High-resolution, thermal array print head.
• Print-out Modes: Manual or automatic, user-configurable.
• On/Off Control: Front panel and paddle
• Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

         *AED Mode:-

• AED Function: Auto analyzer and charge ×3 with programmable auto energy level selection, screen prompts, and voice prompts selectable.
“• Shockable Rhythms:

-Ventricular fibrillation.
-Ventricular tachycardia
-QRS complex wave duration”

Change control: Control on device front panel, Press Key on Paddle.

          *Manual Mode:-

• Energy Selection: Selectable at 2,5,7,10,20,30,50,70,100,150,200,360, joules.
• Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-Wave. “SYNC” message displayed on monitor

          *SpO2 Module(optional)

• Measurement Range: 30-100%, ± 2% between 80%-90% Other ± 5%
• Alarm Range: User set high limit and low limit
• Alarm Accuracy: ±10% within setting values
• Alarm time Accuracy: less than 12 sec

 