CUR2103 C50 Instrument

Product Rating:
5/5

Description

**BD Phoenix M50 Automated Microbiology System :-Giving you confidence in accurate detection of antimicrobial resistance

**BD Phoenix M50 Automated Microbiology System:-

*Build y our future lab with BD Phoenix M50:-

  • The BD Phoenix M50 carousel holds 52 panel holders in two tiers. Each tier holds one normalizer (reference) panel and 25 sample panels. A total of 50 test panels can be loaded on the system at a time.
  • The BD Phoenix M50 ID tests are modifications of the classical methods of biochemical identification. These include tests for fermentation, oxidation, degradation and hydrolysis of various TM substrates. In addition to these, the Phoenix M50 system utilizes chromogenic and fluorogenic substrates as single carbon source substrates in the identification of organisms.
  • The BD Phoenix M50 AST test is a modified miniaturized version of the micro-broth TM doubling dilution technique. The Phoenix M50 panel is available in three formats: ID only, AST only, and combination ID/AST testing. The “pour and seal” serpentine design is optimized for safety and lea resistance
  • The BD Phoenix M50 combination panel includes an ID side with dried substrates for bacterial identification and an AST side with varying concentrations for antimicrobial agents, growth and fluorescent controls at appropriate well locations.
  • The instrument tests panels every 20 minutes for up to 16 hours if necessary.

**BD Phoenix M50 :-

  •  Panel Inoculation
  1. Open panel package:-INOCULATE WITHIN2 HOURS.
  2. Prepare Phoenix™ ID Broth:-Inoculate panel with prepared ID Broth within (<_) 60 MINUTES.
  • Add organism to ID Broth.
  • Vortex. Make .50 – .60 McFarland (standard inoculum).
  • Make .20 – .30 McFarland (low inoculum)

3.  Prepare Phoenix™ AST or AST-S Broth:-Inoculate panel with prepared broth within (<_) 30 MINUTES.

  • Add one free falling drop of AST or AST-S Indicator*** into AST or AST-S Broth. Tube can be used for up to 2 hours if exposed to light or up to 8 hours in the dark. Mix by inverting
  • PREPARE AST or AST-S BROTH
  • Add 25 micro prepared ID Broth (standard inoculum)
  • Add 50 micro prepared ID Broth (low inoculum)

4. After panel inoculation, place closure securely on the panel to seal:-Prepare Purity Plate. Using a sterile loop, recover a small drop from the inoculum laid either before or after inoculating the panel. Inoculate on agar plate (any appropriate medium) for purity check. Incubate plates for 18-24 h at 35°C under appropriate conditions.

5. Load panel(s) into BD Phoenix instrument within after inoculation. (<_) 30 MINUTES

**BD Phoenix™ M50 MPD Identification Technology :-

*High-level accuracy, ease-of-use :-

  • High-level accuracy and ease-of-use are the T Mb benchmarks of BD Phoenix M50 Identification, made possible by the use of MPD (Multi-Parameter Determination) Identification Technology.
  • BD Phoenix M50 MPD Technology incorporates multiple time point databases, static and dynamic measurements, and 45 substrates that employ both chromogenic and fluorogenic detection methods in the same panel. This technology gives rise to the potential of more than 175 trillion biochemical profiles in Phoenix, leading to a very high degree of accuracy and a very low rate of “No Identification.
  • A nether advantage of BD Phoenix M50 MPD Technology is the ease-of-use that it affords the customer by eliminating the need for off line tests, and allowing for a wide range of primary isolation media. It also helps to keep supplemental testing to a minimum while providing extensive taxa coverage.
  • The unique combination of chromogenic and autogenic substrates, together with the five independent time specific data bases gives a median time to ID result of three hours*
  • one of the basic requirements for optimized patient treatment and control of nosocomial infections and emerging resistance is highly accurate microbial identification in the fastest possible time.

**BD Phoenix™ M50 AST Advantage:-

*Detecting Resistance Today and in the Future :-

  • The BD Phoenix M50 Susceptibility System incorporates the use of an oxidation reduction indicator, turbidimetric growth detection, full on panel antimicrobial concentrations and TM the BDX pert System. Together these TM make-up the BD Phoenix M50 AST Advantage System resulting in rapid, accurate and reliable antimicrobial susceptibility results. Result s are enhanced by specific delayed resistance algorithms, providing assurance that TMP hoe nix M50 results are rapid and accurate, preventing very Major Errors.
  • One of the major goals of the microbiologist is to obtain a highly accurate AST result and to provide the best possible results to the clinician’
  • Continuous measurements of changes to the indicator, as well as bacterial turbidity, are used for detecting bacterial growth. BD TM Phoenix M50 is the only system to employ these two technologies. The inclusion of all reported antimicrobial concentrations on the panel, without skipping any, provides you with a true MIC in the concentration range. This provides the foundation for detection of emerging resistance.

**BD Phoenix™M50 Emerge :-

*The more we have, the safer you are Confirmation is the key feature BD:-

  • Accurate detection of carbapenem- resistant Enterobacteriaceae
  • AST-only extended panels raise confidence in the detection of antimicrobial resistance
  • More drugs and wide range of serial two-fold dilutions for many key antibiotics
  • Real MIC detection and rapid AST TM
  • The BD Expert system and BD TM Epic enter systems for better detection, expertise and real-time communication.

*BD Phoenix™M50 Emerge extended AST-only panels :-

  • Wide selection of drugs and serial two-fold dilutions for any key antibiotics
  • In line with CLSI and EUCAST guidelines
  • Embedded detection of resistance markers

**BD Phoenix™ M50 Resistance marker detection:-

*Confirmation is the key feature :-Confirmatory extended spectrum beta-lactamase (ESBL) testing for Escherichia coli, Klebsiella pneumoniae and Klebsiella oxytocic.

*Confirmation is the key feature of the BD Phoenix M50 ESBL Resistance Marketer Detection

  • Definitive beta-lactamase detection in staphylococci
  • Methicillin Resistance in Staphylococcus aureus
  • Predictive Mecca detection utilizing Cefoxitin for Staphylococcus aureus
  • Vancomycin resistance in enterococci
  • High-level aminoglycoside resistance in enterococci
  • Vancomycin resistance in Staphylococcus aureus

*All resistance marker testing is included on every panel of the appropriate type so there is no need for additional tests or added incubation. This results in faster reporting and less additional or repeat testing.

**BD Phoenix™ M50 ASSIST :-Automated & Scalable Solution for Identification and Susceptibility Testing

* Automated: Enjoy the best experience in automation. Improve time to results and also standardization & TM traceability (BD Phoenix M50)

*Scalable: Enable step by step modularity

* Solution: Bring flexibility, traceability & connectivity with the TMBD Epic enter integrated data management system

* Identification: Experience the latest rapid ID technology with the TM TMBD Bruker MALDI Biotype

*Susceptibility Testing: Use state of the art automated AST testing with BD TM Phoenix M50 and a comprehensive BBLTM Sense TM Disc portfolio

**BD Phoenix™ M50 Modularity:-Gain efficiency, adapt swiftly within a small footprint

*The new BD Phoenix M50 ID/AST system TM delivers :-

  • Modularity
  • Reliability
  • Affordability and
  • High quality susceptibility results needed by clinical microbiology laboratories within a small

*Microbiology laboratories can now combine any of these modules to help gain efficiencies, adapt swiftly to changes in activity and accelerate ID/AST results reporting while maintaining control of costs.

*Experience built-in modularity with the BD Phoenix M50 ID/AST system. Whether your ID/AST testing volume is increasing or highly variable, BD Phoenix TM M50 adapts by doubling capacity within a small footprint.

*It’s as simple as stack, plug and work. The combination of two BD Phoenix M50 ID/AST systems offers your TM laboratory redundancy, thus maximizing your uptime.

**BD Phoenix M50 Modularity:-

  •   Expand modularity beyond ID/AST and Maximize laboratory efficiency
  • The modularity of BD BACTEC FX40 and the BD Phoenix M50 ID/AST system offers an efficient and affordable blood culture and ID/AST solution for low-to-mid volume laboratories.
  • With demonstrated detection performance, reliability, dependability, innovation and standardization, the BD BACTEC FX40 blood culture and BD Phoenix M50 ID/AST systems form a natural partnership.
  • State of the art Mass Spectrometry identification coupled with rapid and accurate resistance detection not only supports your goal to maximize laboratory efficiency, but also gives you the confidence you need to accelerate ID/AST results reporting.

**BD Epicenter:-monitor…Analyze…Communicate

*A fully integrated and homogeneous systems :-  The BD Phoenix M50 and BD EpiCenter systems have been developed by BD and are designed to work seamlessly together – The BD Phoenix M50-EpiCenter system will continue to grow as new panels, new drugs or new resistance markers and customer requirements evolve.

*New Surveillances and infection control views:-  The new views provide you with material to monitor antimicrobial resistance, detect emerging trends, evaluate the infection’s spread in

*A new generation Expert system – BD Epic are :-  In order to better monitor antimicrobial resistance and nosocomial infection, BD Epi CARE allows you to develop your own expert rules and alarms according to your laboratory practices, specific requirements and local antibiotic policies – it can help you to track and alerts you in real time when specific isolates detected require focus [impossible phenotype, new resistance patterns].

* The perfect companion for your Laboratory Information System (LIS):-The BD Epi Center system has been designed to be easily interfaced to the LIS – It is now compatible with the major LIS vendors in Europe, exchanging in real-time an extensive list of patient information including results and storing it within the BD Epi Center database on a long-term basis. BD Epi Center guarantees you rapid access to your patients’ historical microbiology results at any time and the freedom to query, analyze and report your microbiology results and surveillance.

**BD Phoenix M50:- Instrument Technical Specifications

* Instrument Panel Capacity:-

  • 1 Bed Phoenix M50: 50 Panel Cal# 443624
  • 2 Bed Phoenix M50: 100 Panels
  • One tablet runs up to two units

*Physical Dimensions:-

  • Height 21 in(535 mm)
  • Width 32 in(815 mm)
  • Depth 30 in (765 mm)
  • Clearance Right 21.5 in (546 mm)
  • Clearance Left ,Rear 3 in (76 mm)
  • Clearance Front 18 in (457 mm)
  • Weight Empty 118 Ib (53.5 kg)
  • Weight Full 127 Ib (57.6 kg)

*Operating Conditions:-

  • Temperature 18-30 °C (64,4-86°F)
  • Humidity 20-80% RH, non-condensing
  • Locations Level surface, No direct sunlight, no direct heat
  • Altitude 2000 meters
  • Noise at 1 m ≤ 55 dB using ANSI Type 2 sound meter

*Electrical Requirements:-

  • Input Voltage 100240 VAC
  • Input current 6 Amp
  • Input Line Frequency 50/60 Hz

Reviews

There are no reviews yet.

Be the first to review “CUR2103 C50 Instrument”

Your email address will not be published.

Shopping Basket