CUR1039 Coagulation Analyzer

Product Rating:
5/5

Description

**Product Description:-

Description:

1. For End Point Method: Storage of ABS for Reagent Blank.

2. For Kinetic Test: 

  • On Line Graph and OD. Graph Editing
  • Facility after the test.
  • Estimation of result during test / delta.

3. Multi Point Calibration for Endpoint, Fix time and Kinetics with graph.
4. Storage of cut off value.

  • Storage of multi-standard curve.
  • Robotic Friendly design.
  • Self Check & Self Calibration.

5. Programmable measurement positions.

  • Fiber Optic Guide reading chamber.
  • Front loading, Self-centering strip carrier.

6. Manual / Auto Start.

  • Single Measuring Channel
  • Coagulation test like. PT with parameter ISI Value / INR / Ratio and APTT : Seconds.

7. Integrated Incubation Timer.

  • Incubation System: 9 position for test tubes. 9 position for Cuvettes at 37°C

Main Feature:

  • User friendly software
  • Editing of patient ID, Name (12 characters), Factor
  • Print out of laboratory name & Doctor’s name.
  • Coagulation test like PT with Magnetic Stirrer.
  • Storage of 2000 test results in the memory with patient ID.
  • PS2 Keyboard connection optional.
  • Lamp Saver mode.

Methods Of Calculations:

  • Absorbance
  • End Point with standard / factor
  • Kinetics
  • Fixed time
  • Differential
  • Coagulation
  • Multipoint up to 10 standards

Aspiration System: Continuous flow system with bi-directional Pump.
Cuvettes: Dual Mode

  • Flow Cell of 18 µL

Removable Cuvettes: Macro, Semi Micro, Micro

Specifications:

Coagulation:

Mixing by magnetic motor / stirrer INR / ISI Value % / Seconds Auto / Manual start
Parameters PT / APTT / Fibrinogen
Filter 405 nm / 630 nm.
Elisa strip reader:
Wells 8 position
Filters 405 nm/450 nm / 630 nm
Methods Cut-off / Multi-standard with EP / KIN / Fix Time
O.D. Range 0 – 3.5A
Optical system:
Principle Absorption Spectrometry
Range of measurement From – 0.1 to 3.0A
Nominal spectral range Automatic via filter wheel
Filters 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth 10 nm (± 2nm)
Reading error ± 5% at 0.10 A
± 2% at 1.00 A
± 2% at 2.00 A
Light source Halogen lamp
Zero Automatic
Settings Monochromatic and Biochromatic readings.
Detector Schottky type Photodiode – Silicon
Thermostat system: 
Peltier regulated 25°, 30° 37°C program
Accuracy ± 0.2°C